Laurel-electronics Custom ASCII Protocol For Laureate Series 2 Digita Manuel d'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
37
10.2 DPM 3-BYTE RAM MEMORY DATA
Format for all items except Scale Factor: MS byte Mid byte LS byte
XX XX XX
Format for Scale Factor: *X XX XX
The 4-bit MS nibble “*” sets the polarity and decimal point according to the following table:
Positive Negative Decimal Point
1
2
3
4
5
6
9
A
B
C
D
E
XXXXX.
XXXX.X
XXX.XX
XX.XXX
X.XXXX
.XXXXX
Note: Hex values are 2's complement and absolute values.
10.3 DPM HEX ADDRESSES
MS Mid LS Description
A1 (L)
9E (L)
1B (U)
18 (U)
9B (L)
98 (L)
8F (L)
8C (L)
15 (U)
12 (U)
89 (L)
86 (L)
A0
9D
1A
17
9A
97
8E
8B
14
11
88
85
9F
9C
19
16
99
96
8D
8A
13
10
87
84
Analog high value
Analog low value
Deviation, Alarm4
Deviation, Alarm3
Deviation, Alarm2
Deviation, Alarm1
Offset value
Scale factor
Setpoint4
Setpoint3
Setpoint2
Setpoint1
Vue de la page 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 55 56

Commentaires sur ces manuels

Pas de commentaire