DIGIT SELECT KEY
VALUE SELECT KEYMENU KEY
-18-
SourcE
Source of alarm operation
(only enabled if relay output
installed)
ALSEt
Alarm Operation Setup
(only enabled if relay output
installed)
0 Filtered item
1 Item 1
2 Item 2
3 Item 3
0 Filtered item
1 Item 1
2 Item 2
3 Item 3
0 relay 1 on, relay2 on
1 relay 1 off, relay2 on
2 relay 1 on, relay2 off
3 relay 1 off, relay2 off
0 AL1 nonlatching
AL2 nonlatching
1 AL1 latching
AL2 nonlatching
2 AL1 nonlatching
AL2 latching
3 AL1 latching
AL2 latching
0 AL1 active high
AL2 active high
1 AL1 active low
AL2 active high
2 AL1 disabled
AL2 active high
3 AL1 active high
AL2 active low
4 AL1 active low
AL2 active low
5 AL1 disabled
AL2 active low
6 AL1 active high
AL2 disabled
7 AL1 active low
AL2 disabled
8 AL1 disabled
AL2 disabled
00
Compare Alarm 1 to:
00
Compare Alarm 2 to:
00000
Relay output status when
alarm active (On or off)
00000
Relay output status when
alarm active (Latching or
nonlatching)
00000
00000
Alarm status
If deviation > 0, then:
active high = energizes out-
side deviation band
active low = energizes inside
deviation band