Laurel-electronics LT SERIES TRANSMITTERS ANALOG INPUT Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Laurel-electronics LT SERIES TRANSMITTERS ANALOG INPUT. Laurel Electronics LT SERIES TRANSMITTERS ANALOG INPUT User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
LT SERIES
TRANSMITTERS
ANALOG INPUT
4-20 MA OUTPUT & RS232
/
RS485 I/O
USER MANUAL
LAUREL Electronics Inc.
3183-G Airway Ave, Costa Mesa, CA, 92626, USA
Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.com
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - TRANSMITTERS

LT SERIES TRANSMITTERS ANALOG INPUT 4-20 MA OUTPUT & RS232 / RS485 I/O USER MANUAL LAUREL Electronics Inc. 3183-G Airway A

Page 2 - 1. ORDERING GUIDE

- 10 - Click on DPM => Get Setup to retrieve the current setup information from your DPM trans-mitter, then on View => Setup, which w

Page 3 - 2. TABLE OF CONTENTS

- 11 - Click on the Filter tab to set to set up filtering for your readings. The filter time constant can be automatic, be specified in seconds, or

Page 4 - 3. PRODUCT OVERVIEW

- 12 - Click on the Communication tab to view the communication parameters that you used to establish default communications with yo

Page 5 - 5. SAFETY CONSIDERATIONS

- 13 - ADDITIONAL FEATURES • The Commands pull-down menu allows you to execute certain functions by using your computer mouse. This men

Page 6 - 6. TRANSMITTER FIELD WIRING

- 14 - Graph • The Jumpers pull-down menu shows jumper positions for the selected signal conditioner boards and the main board, duplica

Page 7 - P6 - SIGNAL INPUT DETAIL

- 15 - 8. OPENING YOUR TRANSMITTER CASE WHEN TO CHANGE JUMPERS Most users will never have the need to open the transmitter case. The t

Page 8

- 16 - 9. DC SIGNAL CONDITIONER BOARD JUMPER SETTINGS Five voltage and four current ranges are jumper selectable. These also have to b

Page 9

- 17 - 10. AC RMS SIGNAL CONDITIONER BOARD JUMPER SETTINGS Five voltage and four current ranges are jumper selectable. These also have to be select

Page 10

- 18 - 11. LOAD CELL SIGNAL CONDITIONER BOARD JUMPER SETTINGS Five ranges are jumper selectable. These also have to be selected in Instrument Setup

Page 11 - Relay Alarms

- 19 - 12. THERMOCOUPLE SIGNAL CONDITIONER BOARD JUMPER SETTINGS Seven thermocouple types are jumper selectable. These also have to be selected i

Page 12

- 2 - 1. ORDERING GUIDE Configure a model number in this format: LT20DCV1, CBL04 Transmitter Type LT...4-20 mA, 0-20 mA or 0-10V isolated an

Page 13

- 20 - 13. RTD & OHMS SIGNAL CONDITIONER BOARD JUMPER SETTINGS The same signal conditioner board is used for 4 RTD types and 5 resistance range

Page 14

- 21 - 14. MAIN BOARD JUMPER SETTINGS E1E4E3E2abcaba bcdE6abcd Serial Signal Duplex Jumpers Termination Resistor* Full None E6 a = Transmit E6 c

Page 15

- 22 - 15. DUAL RELAY OPERATION Dual solid state relays are standard and can operate in a basic alarm mode, in a hysteresis band mode, or in

Page 16

- 23 - 16. INPUT SIGNAL FILTERING A moving average filter is selectable in software to process the internal digital readings, which are taken a

Page 17

- 24 - 18. CUSTOM CURVE LINEARIZATION Curve.exe is a DOS-based, executable PC program used to set up an Extended transmitter so that the interna

Page 18

- 25 - 19. MODBUS PROTOCOL TRANSMITTER COMMUNICATIONS 1.0 GENERAL The Modbus capability conforms to the Modbus over Serial Line Specif

Page 19

- 26 - 4.0 COMMUNICATIONS SETUP Parameters selectable via Instrument Setup software, distributed on CD ROM: Serial Protocol ...

Page 20

- 27 - FC08: Diagnostics Checks communications between the Master and Slave, and returns the count in the Modbus Slave counters (which are reset when

Page 21

- 28 - 6.0 SUPPORTED EXCEPTION RESPONSE CODES Code Name Error Description ---- -------------------- ----------------------------------

Page 22

- 29 - Modbus ASCII Format Byte Number FC Action 1 2 3 4 5 6 7 8 9 10 11 12 13 03 03 Request Response : : MA MA FC FC RA NB RA DD* NR DD

Page 23 - 17. TRANSMITTER CALIBRATION

- 3 - 2. TABLE OF CONTENTS 1. ORDERING GUIDE ...

Page 24

- 30 - 20. CUSTOM ASCII PROTOCOL TRANSMITTER COMMUNICATIONS 1.0 SERIAL COMMUNICATION FORMAT Mode ... Full Duplex (Separate tran

Page 25

- 31 - Values are transmitted in a continuous string with no intervening spaces. If the 5th digit in is set to 1 using Instrument Setup softwar

Page 26

- 32 - Char # Character Description 1 2 3 4 * 0-V A-Z 0-U Command Identifier. Recognition Character. Device Address. 0 addresses all devices, 1-V s

Page 27

- 33 - Peak value reset *1C3 Remote display reset *1C4 Valley reset *1C9 Tare function *1CA Tare reset *1CB 6.0 READING

Page 28

- 34 - General, Reading and Writing Ram Memory Data RAM memory data is read and written as a continuous string of bytes consisting of

Page 29

- 35 - 21. LT SERIES ANALOG INPUT TRANSMITTER SPECIFICATIONS Mechanical Case dimensions...

Page 30

- 36 - Input Signal Noise Rejection CMV, DC to 60 Hz...

Page 31

- 37 - Load Cell & Microvolt Input Range Input Resistance Input Error ±20.000 mV ±50.000 mV ±100.00 mV ±250.00 mV ±500.00 mV 1 GΩ 0.01% of FS ±

Page 32

- 38 - Over-voltage protection ...125 Vac Open sens

Page 33

- 39 -

Page 34

- 4 - 3. PRODUCT OVERVIEW This manual covers LT Series DIN rail transmitters with isolated 4-20 mA and RS232/RS485 outputs, dual relay

Page 35

- 40 - 22. WARRANTY Laurel Electronics Inc. warrants its products against defects in materials or workmanship for a period of one year from the dat

Page 36

- 5 - 4. RECEIVING & UNPACKING YOUR TRANSMITTER Your transmitter was carefully tested and inspected prior to shipment. Should the transmitter b

Page 37

- 6 - 6. TRANSMITTER FIELD WIRING SignalconditionerboardP3 Solidstate relaysP1 PowerinputP6 Signalinput &excitationoutputP2 Serialdata I/OP

Page 38

- 7 - P6 - SIGNAL INPUT DETAIL2-Wire Process Transmitter+-Excitation return 1+ Excitation 2- Signal input 3+ Signal input 4DC & Exter

Page 39

- 8 - 7. PROGRAMMING YOUR TRANSMITTER OVERVIEW Our transmitters are easily programmed using a PC with an RS232 port and Instrument Setup (IS) softw

Page 40 - 22. WARRANTY

- 9 - In the Establish Communications screen, select your Com Port and 9600 as the Baud Rate. You will be able to change your protocol and baud rate

Commentaires sur ces manuels

Pas de commentaire