Laurel-electronics LT SERIES TRANSMITTERS PULSE INPUTS Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Laurel-electronics LT SERIES TRANSMITTERS PULSE INPUTS. Laurel Electronics LT SERIES TRANSMITTERS PULSE INPUTS User Manual [en] [es] [fr] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
LT SERIES
TRANSMITTERS
PULSE INPUTS
4-20 MA OUTPUT & RS232
/
RS485 I/O
USER MANUAL
LAUREL Electronics Inc.
3183-G Airway Ave, Costa Mesa, CA, 92626, USA
Tel: (714) 434-6131 Fax: (714) 434-3766 Website: www.laurels.com
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - TRANSMITTERS

LT SERIES TRANSMITTERS PULSE INPUTS 4-20 MA OUTPUT & RS232 / RS485 I/O USER MANUAL LAUREL Electronics Inc. 3183-G Airw

Page 2 - 1. ORDERING GUIDE

- - 10 - Click on Counter => Get Setup to retrieve the current setup information from your counter transmitter, then on View =

Page 3 - 2. TABLE OF CONTENTS

- - 11 - Click on the Filter tab to set to set up filtering for your readings. Click on the Relay Alarms tab to set up your transmitter’s t

Page 4 - 3. PRODUCT OVERVIEW

- - 12 - Click on the Communication tab to view the communication parameters that you used to establish default communications wi

Page 5 - 5. SAFETY CONSIDERATIONS

- - 13 - ADDITIONAL FEATURES • The Commands pull-down menu allows you to execute certain functions by using your computer mouse. Th

Page 6 - 6. TRANSMITTER FIELD WIRING

- - 14 - Graph • The Jumpers pull-down menu shows jumper positions for the selected signal conditioner boards and the main board, d

Page 7 - 2-Wire Process Transmitter

- - 15 - 8. OPENING YOUR TRANSMITTER CASE WHEN TO CHANGE JUMPERS Most users will never have the need to open the transmitter case.

Page 8

- - 16 - 9. DUAL CHANNEL PULSE OR AC INPUT SIGNAL CONDITIONER BOARD This signal conditioner board is used for the frequency, rate, peri

Page 9

- - 17 - Function Block Jumper Setting Frequency Response A0 & B0 - b a 1 MHz max 30 kHz max 250 Hz max Bias Resistor A1 & B1 a b 10 k

Page 10

- - 18 - • Rates A+B, A-B, AxB, A-B, A/B, A/B-1 (Extended counter) can output arithmetic combi-nations of Rates A and B (Item #1), Ra

Page 11 - Relay Alarms

- - 19 - together and selecting a positive or negative edge to start (Slope A) and the opposite polarity edge to stop (Slope B). If multipl

Page 12

- - 2 - 1. ORDERING GUIDE Configure a model number in this format: LT60VF1, CBL04 Transmitter Type LT...Pulse input transmitter with 4-20 mA, 0-

Page 13

- - 20 - 10. V-TO F CONVERTER SIGNAL CONDITIONER BOARD This process receiver signal conditioner board converts 0-1 mA, 4-20 mA or 0-10

Page 14

- - 21 - 11. QUADRATURE SIGNAL CONDITIONER BOARD This signal conditioner can be used for quadrature position (Basic or Extended main board) o

Page 15

- - 22 - Phase for Up Count E7 A positive, negative B transition (A leads B) A positive, positive B transition (B leads A) none a Count-by Op

Page 16

- - 23 - 12. MAIN BOARD JUMPER SETTINGS E1E4E3E2abcaba bcdE6abcd Serial Signal Duplex Jumpers Termination Resistor* Full None E6 a = Transmi

Page 17 - by entering a

- - 24 - 13. DUAL RELAY OPERATION Dual solid state relays are standard and can operate in a basic alarm mode, in a hysteresis band mode, or

Page 18

- - 25 - band is often used to minimize relay chatter. A wide hysteresis band can be used for on-off control applications. The hyster

Page 19

- - 26 - Calibration of the quartz crystal is easily accomplished using Instrument Setup software. Select Calibration from the Main Menu. A

Page 20

- - 27 - 17. MODBUS PROTOCOL TRANSMITTER COMMUNICATIONS 1.0 GENERAL The Modbus capability conforms to the Modbus over Serial Line

Page 21

- - 28 - 4.0 COMMUNICATIONS SETUP Parameters selectable via Instrument Setup software, distributed on CD ROM: Serial Protocol ...

Page 22

- - 29 - FC08: Diagnostics Checks communications between the Master and Slave, and returns the count in the Modbus Slave counters (which are rese

Page 23

- - 3 - 2. TABLE OF CONTENTS 1. ORDERING GUIDE ...

Page 24

- - 30 - 6.0 SUPPORTED EXCEPTION RESPONSE CODES Code Name Error Description ---- -------------------- -----------------------------

Page 25 - 15. TRANSMITTER CALIBRATION

- - 31 - Modbus ASCII Format Byte Number FC Action 1 2 3 4 5 6 7 8 9 10 11 12 13 03 03 Request Response : : MA MA FC FC RA NB RA DD*

Page 26

- - 32 - 18. CUSTOM ASCII PROTOCOL TRANSMITTER COMMUNICATIONS 1.0 SERIAL COMMUNICATION FORMAT Mode ... Full Duplex (Separate

Page 27

- - 33 - Values are transmitted in a continuous string with no intervening spaces. If the 5th digit in is set to 1 using Instrument Setup s

Page 28

- - 34 - Char # Character Description 1 2 3 4 * 0-V A-Z 0-U Command Identifier. Recognition Character. Device Address. 0 addresses all devices,

Page 29

- - 35 - Peak value reset *1C3 Remote display reset *1C4 Valley reset *1C9 Tare function *1CA Tare reset *1CB 6.0 RE

Page 30

- - 36 - General, Reading and Writing Ram Memory Data RAM memory data is read and written as a continuous string of bytes consisting

Page 31

- - 37 - 19. LT SERIES PULSE INPUT TRANSMITTER SPECIFICATIONS Mechanical Case Dimensions ...

Page 32

- - 38 - DUAL CHANNEL SIGNAL CONDITIONER Crystal Accuracy at 25ºC...

Page 33

- - 39 -

Page 34

- - 4 - 3. PRODUCT OVERVIEW This manual covers LT Series DIN rail transmitters with isolated 4-20 mA and RS232/RS485 outputs, dua

Page 35

- - 40 - 20. WARRANTY Laurel Electronics Inc. warrants its products against defects in materials or workmanship for a period of one year from t

Page 36

- - 5 - 4. RECEIVING & UNPACKING YOUR TRANSMITTER Your transmitter was carefully tested and inspected prior to shipment. Should the transmi

Page 37

- - 6 - 6. TRANSMITTER FIELD WIRING SignalconditionerboardP3 Solidstate relaysP1 PowerinputP6 Signalinput &excitationoutputP2 Serialdat

Page 38

- - 7 - P6 - SIGNAL INPUT DETAILExcitation return 1+ Excitation 2- Signal input 3+ Signal input 42-Wire Process Transmitter+-Excitati

Page 39

- - 8 - 7. PROGRAMMING YOUR TRANSMITTER OVERVIEW Our transmitters are easily programmed using a PC with an RS232 port and Instrument Setup (IS

Page 40 - 20. WARRANTY

- - 9 - In the Establish Communications screen, select your Com Port and 9600 as the Baud Rate. You will be able to change your protocol and bau

Commentaires sur ces manuels

Pas de commentaire